Oxygen Generator | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Usable device for oxygen generation—must be linked to vents to work. Also recharges oxygen tanks. | ||||||||||
Statistics* | ||||||||||
Power Consumption | 5 + 1000 kW | |||||||||
Item Slots | 5 Oxygen Tank slots | |||||||||
Generated Oxygen | 400 | |||||||||
Repairable | ||||||||||
Required Skill | Mechanical Engineering 55 | |||||||||
Required Item | Wrench | |||||||||
|
Oxygen Generator: Difference between revisions
From Official Barotrauma Wiki
(→Default Submarines Oxygen Generation: Added Barsuk and Camel, updated Typhon 2) |
(Cleaned up the page. Moved vent stuff to Vent) |
||
Line 1: | Line 1: | ||
{{Version|0. | {{Version|0.21.6.0}}__NOTOC__ | ||
{{Infobox Tabs|Oxygen Generator|{{Installations infobox | {{Infobox Tabs|Oxygen Generator|{{Installations infobox | ||
| imagewidth = 140 | | imagewidth = 140 | ||
Line 35: | Line 35: | ||
| repairtype = Mechanical | | repairtype = Mechanical | ||
| repairskill = 55 | | repairskill = 55 | ||
}} | }}}} | ||
{{ | The '''{{PAGENAME}}''' is an [[:Category:Installations|installation]]. | ||
}} | |||
=Function= | =Function= | ||
The Oxygen Generator is a powered machine that distributes [[Oxygen]] through | The Oxygen Generator is a powered machine that distributes [[Oxygen]] through linked [[Vent]]s and refills [[Oxygen Tank]]s. Vents distribute Oxygen proportionate to the volume of Hull the vent is in compared to all linked Vents. For example, 4 vented rooms of equal size will each receive 25% of the Generator's output. | ||
Additionally, the Oxygen Generator holds 5 [[Oxygen Tank|Oxygen Tanks]]. Each get filled at a rate of 2.5% condition/second, or 40 seconds to fill a completely empty Oxygen Tank. This does not impact the Oxygen generation rate. | Additionally, the Oxygen Generator holds 5 [[Oxygen Tank|Oxygen Tanks]]. Each get filled at a rate of 2.5% condition/second, or 40 seconds to fill a completely empty Oxygen Tank. This does not impact the Oxygen generation rate. |
Revision as of 01:18, 11 March 2023
Data is potentially outdated | |
Last updated for version 0.21.6.0 Last mentioned in changelog 1.0.13.0 The current game version is 1.4.6.0 |
Shuttle Oxygen Generator | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Usable device for oxygen generation—must be linked to vents to work. Also recharges oxygen tanks. | ||||||||||
Statistics* | ||||||||||
Power Consumption | 1000 kW | |||||||||
Item Slots | 5 Oxygen Tank slots | |||||||||
Generated Oxygen | 400 | |||||||||
Repairable | ||||||||||
Required Skill | Mechanical Engineering 55 | |||||||||
Required Item | Wrench | |||||||||
|
Oxygen Generator | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Usable device for oxygen generation—must be linked to vents to work. Also recharges oxygen tanks. | ||||||||||
Statistics* | ||||||||||
Power Consumption | 1000 kW | |||||||||
Item Slots | 5 Oxygen Tank slots | |||||||||
Generated Oxygen | 5000 | |||||||||
Repairable | ||||||||||
Required Skill | Mechanical Engineering 55 | |||||||||
Required Item | Wrench | |||||||||
|
The Oxygen Generator is an installation.
Function
The Oxygen Generator is a powered machine that distributes Oxygen through linked Vents and refills Oxygen Tanks. Vents distribute Oxygen proportionate to the volume of Hull the vent is in compared to all linked Vents. For example, 4 vented rooms of equal size will each receive 25% of the Generator's output.
Additionally, the Oxygen Generator holds 5 Oxygen Tanks. Each get filled at a rate of 2.5% condition/second, or 40 seconds to fill a completely empty Oxygen Tank. This does not impact the Oxygen generation rate.
Stored Oxygen Tanks are not protected from fire and can burn and explode.
Oxygen Generators do not deteriorate from being submerged.
Connection Panel
Connection Panel for Oxygen Generator Hover over pins to see their descriptions. | ||||||||
---|---|---|---|---|---|---|---|---|
| ||||||||
Requires: Screwdriver |
Default Submarines Oxygen Generation
Submarine | Oxygen Generation | Vents | Average Room Maximum Occupancy |
---|---|---|---|
Azimuth | 400 | 10 | 5.7 |
Barsuk | 400 | 7 | 8.2 |
Berilia | 1,600 | 25 | 9.1 |
Camel | 400 | 16 | 3.6 |
Dugong | 400 | 9 | 6.3 |
Humpback | 750 | 9 | 11.9 |
Herja | 700 | 12 | 8.3 |
Kastrull | 750 | 17 | 6.3 |
Orca | 400 | 10 | 5.7 |
Orca 2 | 650 | 15 | 6.1 |
R-29 | 800 | 16 | 7.1 |
Remora | 1,200 | 13 | 13.1 |
Typhon | 1,000 | 20 | 7.1 |
Typhon 2 | 600 | 15 | 5.7 |
Winterhalter | 1750 | 9 | 27.7 |
Trivia
- The Typhon 2 features the Shuttle Oxygen Generator instead of the regular generator.
Media
-
Oxygen Generator active ambience
See Also
Installations | |
---|---|
Submarine Weapons | |
Small Turrets
|
Large Turrets
|
Loaders
| |
Other
| |
Navigation | |
Machines | |
Electrical | |
Structure | |
Other | |
Alien | |