Oxygen Generator

From Official Barotrauma Wiki
(Redirected from Vent)
Jump to: navigation, search
Version Checkmark False.png Data is potentially outdated
Last updated for version 0.15.22.1
The current game version is 0.18.15.2
Notes: Outdated vent image

Oxygen Generator
Oxygen Generator.png
ID: oxygenerator
Usable device for oxygen generation—must be linked to vents to work. Also recharges oxygen tanks.
Machine 
Statistics* 
Power Consumption 5 + 1000 kW 
Item Slots 5 Oxygen Tank slots 
Generated Oxygen 400 
Repairable
Required Skill Mechanical Engineering 55
Required Item Wrench.png Wrench

Shuttle Oxygen Generator
Shuttle Oxygen Generator.png
ID: shuttleoxygenerator
Usable device for oxygen generation—must be linked to vents to work. Also recharges oxygen tanks.
Machine 
Statistics* 
Power Consumption 1000 kW 
Item Slots 5 Oxygen Tank slots 
Generated Oxygen 400 
Repairable
Required Skill Mechanical Engineering 55
Required Item Wrench.png Wrench

Oxygen Generator
Outpost Oxygen Generator.png
ID: outpostoxygenerator
Usable device for oxygen generation—must be linked to vents to work. Also recharges oxygen tanks.
Machine 
Statistics* 
Power Consumption 1000 kW 
Item Slots 5 Oxygen Tank slots 
Generated Oxygen 5000 
Repairable
Required Skill Mechanical Engineering 55
Required Item Wrench.png Wrench

Vent
Vent.png
ID: vent
Oxygen output point. Must be linked to an oxygen generator to work.
Machine

Loose Vent
Vent.png
ID: loosevent
A place to stash things of dubious nature.
Machine 
Statistics* 
Item Slots 1 Small/Medium slot

The Oxygen Generator is an installation. It supplies linked Vents with Oxygen and refills Oxygen Tanks.

Function

The Oxygen Generator is a powered machine that distributes Oxygen through Vents. Vents distribute Oxygen proportionate to the volume of Hull the vent is in compared to all linked Vents. For example, 4 vented rooms of equal size will each receive 25% of the Generator's output.

Additionally, the Oxygen Generator holds 5 Oxygen Tanks. Each get filled at a rate of 2.5% condition/second, or 40 seconds to fill a completely empty Oxygen Tank. This does not impact the Oxygen generation rate.

Stored Oxygen Tanks are not protected from fire and can burn and explode.

Oxygen Generators do not deteriorate from being submerged.

Connection panel

Connection Panel for Oxygen Generator
Hover over pins to see their descriptions.
Connection Port.png
power_in
Connecting a power source to this input will supply the oxygen generator with power.
condition_out
Connection Port.png
Outputs the Oxygen Generator's current condition. (0-100)

Default Submarines Oxygen Generation

Submarine Oxygen Generation Vents Average Room Maximum Occupancy
Azimuth 400 10 5.7
Berilia 1,600 25 9.1
Dugong 400 9 6.3
Humpback 750 9 11.9
Herja 700 12 8.3
Kastrull 750 17 6.3
Orca 400 10 5.7
Orca 2 650 15 6.1
R-29 800 16 7.1
Remora 1,200 13 13.1
Typhon 1,000 20 7.1
Typhon 2 500 15 4.7
Winterhalter 1750 9 27.7

Trivia

  • The Typhon 2 features the Shuttle Oxygen Generator instead of the regular generator.

Media

See also

v·d·e·h
Installations
Submarine Weapons
Turrets
Loaders
Other
Navigation
Machines
Electrical
Structure
Other
Alien