Status Monitor: Difference between revisions

From Official Barotrauma Wiki
Jump to: navigation, search
m (Reformatted headers)
(12 intermediate revisions by 7 users not shown)
Line 1: Line 1:
{{Outdated|Needs to be up to date with the [[Version_history/Alpha|current steam version]].}}
{{Version|0.15.13.0}}
{{Installations infobox
{{Installations infobox
| image = Status Monitor.png
| image = Status Monitor.png
Line 6: Line 6:
| powerconsumption = 100
| powerconsumption = 100
}}
}}
The '''Status Monitor''' is an [[:Category:Installations|installation]] in ''[[Barotrauma]]''. It allows players to quickly ascertain the level of water present in each section of the [[:Category:Submarines|submarine]], making attempts to find and fix [[Maintenance#Flooding|floodings]] much easier.
The '''Status Monitor''' is an [[:Category:Installations|installation]] in ''[[Barotrauma]]''. It allows players to quickly ascertain the level of water present in each section of the [[:Category:Submarines|submarine]], making attempts to find and fix [[Maintenance#Flooding|flooding]] much easier.


==Usage==
=Usage=
Using the Status Monitor will bring up a schematic of the current submarine, in which every area is represented by white-bordered rectangles. The horizontal borders divide each layer based on ceiling/floor placement, while the vertical borders indicate where [[doors]] are located.
Using the Status Monitor will bring up an interface with 3 possible categories; General Status, Electrical View, and Item Finder.


When an area of the submarine begins filling with water, the Status Monitor will update to show the current level of water in that section, signified by the area on the map filling up with the color blue. It will not display openings through which the water is flowing from, such as open doors or hull breaches. Areas containing [[pump]]s, such as ballast tanks, will also display as being flooded due to the nature of how they work.
==General Status==
The General Status tab displays an overview of each room's hull damage, water level and oxygen quality.


This item can prove useful for isolating the location where floods are occurring,
The current water level in a room is signified by the room filling up with the color blue, hull breaches will glow orange to red depending on damage, and the fill color of a room fading to red depicts the decreasing oxygen quality.
Hovering over a room on will also display the name of the room, as well the exact water level and oxygen quality.


==I/O Interface==
Certain rooms (ballasts, airlocks) may be bordered in blue instead of green to indicate that they are wet rooms. Additionally, smaller outlines will appear wherever there is a door or hatch, and job icons will indicate where certain crew members are located within the submarine.
 
The General Status tab also allows reporting damage/fires/flooding/intruder in specific rooms, the icons located at the bottom can be drag and dropped over a room to give the crew a HUD indicator to it.
 
==Electrical View==
The Electrical View tab displays an overview of the submarine's electrical grid and its condition.
 
It displays the location and condition of all [[Installations]] connected to the electrical grid. (Status Monitors, Batteries, Junction Boxes, Pumps, etc.)
 
Hovering over any of these icons will display extra information relevant to the installation, such as power consumption, durability, or remaining power.
 
==Item Finder==
The Item Finder tab shows a schematic view of the submarine with a search bar under it.
 
Typing the name of any item currently on the submarine will show every instance of that item and their location, however, items held by alive characters will not have their position displayed.
=Connection panel=
{{Connection panel
{{Connection panel
| input1 = power_in
| input1 = power_in
| input1tt = Connecting a power source to this input will supply the Status Monitor with power.|input2=water_data_in|input2tt=Connecting a water detector's signal output to this input will give the Status Monitor information about water level in area where detector is placed.|input3=oxygen_data_in|input3tt=Connecting an oxygen detector’s signal output to this input will give the Status Monitor information about oxygen quality in area where detector is placed.}}
| input1tt = Connecting a power source to this input will supply the Status Monitor with power.
 
| input1color = red
==Gallery==
| input2 = water_data_in
<gallery widths="280" heights="170">
| input2tt = Connecting a water detector's signal output to this input will give the Status Monitor information about water level in area where detector is placed.
Minimap example.png|The Status Monitor displaying a schematic of the [[Aegir Mark III]] on its GUI. Note the areas in blue.
| input3 = oxygen_data_in
| input3tt = Connecting an oxygen detector’s signal output to this input will give the Status Monitor information about oxygen quality in area where detector is placed.
| output1  = condition_out
| output1tt = Outputs the current condition of the status monitor, from 0 to 100.
}}
=Media=
<gallery widths=280 heights=200>
File:Status Monitor GUI general.png|The status monitor of the Typhon 2, set to display the general overview.
File:Status Monitor GUI electrical.png|The status monitor of the Typhon 2, set to display the electrical view.
File:Status Monitor GUI item finder.png|The status monitor of the Typhon 2, set to display the item finder while searching for Fuel Rods.
File:Status Monitor Typhon2.png|(Old) The status monitor of the Typhon 2, with the cursor hovering one of the ballasts.
</gallery>
</gallery>
{{Installations nav}}
{{Installations nav}}
[[Category:Installations]]
[[Category:Installations]]

Revision as of 15:08, 21 June 2022

Data is potentially outdated
Last updated for version 0.15.13.0
Last mentioned in changelog 1.2.8.0
The current game version is 1.2.8.0
Status Monitor
Statistics*
Power Consumption 100 kW
Technical
Identifier {{{identifier}}}
Categories Machines

The Status Monitor is an installation in Barotrauma. It allows players to quickly ascertain the level of water present in each section of the submarine, making attempts to find and fix flooding much easier.

Usage

Using the Status Monitor will bring up an interface with 3 possible categories; General Status, Electrical View, and Item Finder.

General Status

The General Status tab displays an overview of each room's hull damage, water level and oxygen quality.

The current water level in a room is signified by the room filling up with the color blue, hull breaches will glow orange to red depending on damage, and the fill color of a room fading to red depicts the decreasing oxygen quality. Hovering over a room on will also display the name of the room, as well the exact water level and oxygen quality.

Certain rooms (ballasts, airlocks) may be bordered in blue instead of green to indicate that they are wet rooms. Additionally, smaller outlines will appear wherever there is a door or hatch, and job icons will indicate where certain crew members are located within the submarine.

The General Status tab also allows reporting damage/fires/flooding/intruder in specific rooms, the icons located at the bottom can be drag and dropped over a room to give the crew a HUD indicator to it.

Electrical View

The Electrical View tab displays an overview of the submarine's electrical grid and its condition.

It displays the location and condition of all Installations connected to the electrical grid. (Status Monitors, Batteries, Junction Boxes, Pumps, etc.)

Hovering over any of these icons will display extra information relevant to the installation, such as power consumption, durability, or remaining power.

Item Finder

The Item Finder tab shows a schematic view of the submarine with a search bar under it.

Typing the name of any item currently on the submarine will show every instance of that item and their location, however, items held by alive characters will not have their position displayed.

Connection panel

Connection Panel for Status Monitor
Hover over pins to see their descriptions.
power_in
water_data_in
oxygen_data_in
Connecting a power source to this input will supply the Status Monitor with power.
Connecting a water detector's signal output to this input will give the Status Monitor information about water level in area where detector is placed.
Connecting an oxygen detector’s signal output to this input will give the Status Monitor information about oxygen quality in area where detector is placed.
condition_out
Outputs the current condition of the status monitor, from 0 to 100.
Requires: Screwdriver

Media

v·d·e·h
Installations
Submarine Weapons
Small Turrets
Large Turrets
Loaders
Other
Navigation
Machines
Electrical
Structure
Other
Alien